0% VAT on home solar and batteries ends on 31 March 2027, then 5%. Surveys, approvals and installs take weeks, so book early. Get a free quote

Panel installation and wiring

A Year of Data from a 60-Panel UK Solar System: What It Shows

Artisan Electrics installed 60 solar panels and 120 kWh of battery storage at their own Cambridge headquarters. A year later they published the data: 25,500 kWh generated, 90% of site energy covered, 6 MWh exported, and the system ran through a local power cut while nearby buildings closed. The honest conclusion? A considerably smaller system would have done the job. Here is what that data means for anyone sizing a UK solar installation.

Video: "Did I Waste £100,000 on This Solar System?" by Artisan Electrics, a UK solar, battery and EV charging firm based in Cambridge.

MCS installation: a solar and battery system connected to the grid requires an MCS-registered installer. Any solar and battery installation that exports to the grid is MCS-notifiable. Only an MCS-registered installer can certify the system for Smart Export Guarantee eligibility. If the system will export, your DNO must be notified before it is energised (G98 for single-phase systems up to 16A per phase with no battery export, G99 for all other configurations). Working inside the consumer unit or on DC strings always requires a qualified person.

1. What the system comprised

The Artisan Electrics headquarters installation uses 60 solar panels paired with 120 kWh of battery storage and multiple hybrid inverters. The system was designed at a scale appropriate for a commercial workspace, running tools, office equipment, lighting and EV charging across the site.

For context: 60 panels at around 400W each give roughly 24 kWp of installed capacity. The typical UK residential MCS installation is 10 to 16 panels (4 to 6.4 kWp). The Cambridge system is around four to six times larger than a typical home installation, which is why the generation figures look large in absolute terms: the per-panel performance is entirely consistent with residential UK systems.

The 120 kWh battery is similarly scaled up from residential practice. Most UK home batteries are 5 to 15 kWh. The commercial system's battery is sized to capture and redistribute the larger daily surplus that 60 panels generate.

2. What a full year's data showed

Over the course of a full year, the system generated 25,500 kWh. That covered around 90% of the site's total energy use, with 6,000 kWh exported to the grid under the Smart Export Guarantee.

Breaking this down into something meaningful for a residential comparison: 25,500 kWh from roughly 24 kWp installed capacity works out to about 1,060 kWh per kWp per year. For a residential 4 kWp system, that rate would imply around 4,200 kWh annually, which falls comfortably within the typical UK range of 3,500 to 4,500 kWh for a south-facing roof in England.

The 90% self-consumption figure (including battery-shifted generation) illustrates the value of storage. Without the battery, a large portion of the midday generation surplus would have gone straight to the grid at the lower export rate rather than offsetting more expensive imported electricity in the evening.

3. The power cut test

During a local grid outage, the Artisan Electrics site kept running while nearby premises closed. This is what a battery with islanding or backup capability does: when the grid goes down, the inverter switches to standalone mode and continues to supply power from the battery and any available solar generation.

For residential use, this requires a hybrid inverter system with a backup output, configured correctly during installation. It does not happen automatically with a standard string inverter and no battery. If grid backup capability matters to you, raise it at the design stage so the system is specified and wired to deliver it.

The backup capability comes with one important practical limit: the backup output on most residential hybrid inverters is rated at a fraction of the full grid supply capacity. Typically 3 to 5 kW. That is enough for essential loads (lights, fridge, phone charging, perhaps a heat pump on a mild day) but not enough to run everything simultaneously as you would on normal grid power.

4. The sizing lesson

Perhaps the most useful part of the Artisan Electrics data is the candid assessment that came with it: a considerably smaller design would likely have done the job.

This is an important point, coming from the firm that designed and installed the system. It reflects a pattern seen across both commercial and residential solar: systems sized to maximise future-proofing or to feel impressive often end up exporting significant generation at the lower export rate rather than self-consuming it at the higher avoided-import rate.

For a residential buyer, the practical question is: how much surplus solar can your home realistically self-consume, with or without a battery? The answer depends on your daytime occupancy, your evening usage, and how large a battery you can store it in. A system with more panels than your battery can absorb during a typical sunny day will export the excess rather than storing it, and the return on that exported energy is lower than the return on energy you use yourself.

5. What this means for your MCS installation

The Cambridge data is a useful calibration point, but the right size for your system is specific to your property, usage and budget. The key questions to work through with an MCS installer are:

An MCS-registered installer will carry out a site survey and model expected generation using UK irradiance data for your postcode. That is the right basis for a sizing decision. The Cambridge data confirms that more is not always better: right-sizing from the start shortens the payback period and delivers a better return on investment.

Frequently Asked Questions

How much can a UK solar system actually save?

A 10-panel, 4 kWp system on a south-facing UK roof typically generates 3,500 to 4,500 kWh per year. At current electricity prices, self-consuming that generation saves roughly £700 to £1,100 per year for a typical household. Adding a battery to capture midday surplus for evening use can increase that by a further £200 to £400. The Cambridge Artisan Electrics data, at 25,500 kWh from 60 panels, is consistent with these rates when scaled to a residential system.

Can solar panels keep my home powered during a power cut?

Not automatically. A standard grid-tied solar inverter shuts down when grid power is lost, as a safety requirement. To keep essential loads running during a cut, you need a hybrid inverter and battery system configured with a backup output, and the right loads wired through it. The Artisan Electrics site ran through a local outage because its battery had this capability. For residential use, confirm the backup configuration during the design stage: not all systems are set up for it by default.

Is oversizing a solar system a good idea?

Usually not. A system larger than your usage and battery capacity exports the surplus at the Smart Export Guarantee rate, which is typically much lower than what you pay to import. The Artisan Electrics assessment was that a smaller system would have met the site's needs. Right-sizing from the start gives a shorter payback period. If you plan to add an EV charger or heat pump in the future, factor that expected load in now rather than simply buying more panels than you currently need.

Get a site survey and quote See MCS installations